Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

LiHCH Multicore Halogen-free Data Cable

Application

These screened, halogen-free cables are designed for special purpose of data transmission in wind turbines,

suitable for indoor and outdoor installation.

Standards

VDE 0812

Construction

LiHCH

Conductor: Stranded bare copper.

Insulation: Halogen free compound.

Screen: Tinned copper wire braid.

Sheath: Halogen free compound.

Technical Data

Rated Voltage Uo/U (Um):250V

Operating Temperatures:flexing: -5℃~+70℃; fixed: -40℃~+70℃

Minimum Bending Radius:flexing: 10×OD; fixed: 7.5×OD

Flame Retardant:DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1

Halogen Free:VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754

Gases Corrosively:VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754

Oil Resistant:Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
2×0.14 4.1 22
3×0.14 4.3 25
4×0.14 4.5 29
6×0.14 5.1 35
7×0.14 5.1 38
8×0.14 6.0 41
12×0.14 6.5 78
16×0.14 7.2 90
25×0.14 8.7 149
2×0.25 4.7 25
3×0.25 4.9 30
4×0.25 5.2 35
6×0.25 6.2 49
7×0.25 6.2 52
8×0.25 7.3 58
10×0.25 7.7 81
25×0.25 10.9 172
2×0.34 5.1 30
3×0.34 5.3 35
4×0.34 5.9 42
5×0.34 6.4 53
7×0.34 7.0 73
8×0.34 8.0 84
10×0.34 8.5 101
16×0.34 9.6 160
25×0.34 12.1 259
2×0.5 5.8 38
3×0.5 6.1 47
4×0.5 6.5 67
5×0.5 7.2 76
6×0.5 7.8 84
7×0.5 7.8 91
8×0.5 8.9 131
10×0.5 9.5 135
12×0.5 9.8 177
18×0.5 11.7 239
25×0.5 13.9 352
2×0.75 6.2 45
3×0.75 6.5 69
4×0.75 7.2 80
5×0.75 7.8 99
7×0.75 8.3 120
12G0.75 10.7 168
18G0.75 12.4 237
2×1 6.5 72
3×1 7.0 90
4×1 7.5 109
7×1 8.8 171
10×1 11.2 184
12G1 11.3 205
16×1 12.5 250
19G1 13.1 291
2×1.5 7.7 90
3×1.5 8.1 115
5×1.5 9.5 176
12G1.5 13.0 271
18G1.5 15.5 400
15G2.5 19.8 587